Tube of glass fibre laminate

Catalogue <<< INSULATING MATERIALS <<< Insulating sleeving and tube <<< Tube of glass fibre laminate
Order
Amount

 Tube of glass fibre laminate

Tube ТСЭФ represents the layered material made by a method of continuous winding preliminary impregnated epoxy binder roving with subsequent it calcification.

 The tube glass fibre laminate is applied as insulating a material to a complete set of the high-voltage equipment (oil and air switches) for work in transformer oil and on air in conditions of normal relative humidity of an environment and frequency of a current of 50 Hz at temperature from 60°С up to 90°С and also for work in conditions of the raised humidity of an environment (95±2) % and temperature from-60°С up to 155°С.

 As a constructional material fiberglass plastic  pipes are applied in a role обсадных pipes to fastening oil and gas chinks and also in especially harmful manufactures as chemically proof pipes.

 Pipes fiberglass plastic can be applied with success as heat-insulated a material in electric dryers heaters and other equipment Connection of pipes among themselves can be made by means of the formed internal conic groove by means of pasted metal branch pipes and also can be made with external winding on the ends for cutting an external groove.

 TUBE ТСЭФ, CHARACTERISTICS:

 

The name of parameters

Unit of measure

Tubes ТСЭФ

Cylinders ЦСЭФ

Breaking point at a static bend at (15-35) °С 45-75 %, not less

МPа

 

200

 

200

 

Breaking point at compression along an axis at (15-35) °С 45-75 %, not less

МPа

 

100

100

Breaking point at a stretching at (15-35) °С 45-75 %, not less

МPа

 

110

 

-

 

Specific volumetric electric resistance, not less at (15-35) °С 45-75 % after air-conditioning 24 hour/23°С/93 %

Ohm х m

 

5x1010 

1x109

 

5x1010 

1x109

 

Test pressure in a direction in parallel layers of M (90°С), transformer oil

 

During 1 minutes

 

During 5 minutes

kVeff

15

-

15

-

The test pressure in a direction is perpendicular to layers of M (90°С), transformer oil during 1 minutes during 5 min .for walls т. 2-10 mm

-

 

20 -

 

- -

 

Penetrative pressure in parallel layers at a variable pressure of frequency of 50 Hz transformer oil at 90 оС, not less

-

-

-

Tangent of a corner of dielectric losses at frequency of 50 Hz, no more at (15-35) °С 45-75 %

 

At a pressure 103 kV

 

At a pressure 73 kV

 

At a pressure 24 kV

%

 

-

 

0,025

 

Density, not less

g/sm3

 

1,45

 

1,5