Phenolic cotton cloth it is a layered sheet and shaped material on the basis of the cotton fabric impregnated heat-convertible binding.It is well processed by all kinds of machining. It is applied to manufacturing шестерен, plugs, bearings of sliding, panels, linings for amortisation products of technical purpose. Products from textolite provide noiselessness in work, considerably the big service life, smaller relative density in comparison with metal materials.
Phenolic cotton cloth sheet,characteristics:
Mark
Structure
Class Т
Purpose
Dimensions
Phenolic cotton cloth A GOST 2910-74 THAT 05758799-014-96 (for thickness over 50,0 mm)
Cotton fabric, phenol formaldehyde pitch
105°С
For work in transformer oil and on air in conditions of normal relative humidity of 45-75 % at that (15-35) °С and frequency of a current of 50 Hz
Sheets in the size (450-980) х (1000-2480) mm; thickness-0,5-200mm
Constructional textolite ПТК GOST 5-78
Cotton fabric, phenol formaldehyde pitch
105° С
For manufacturing gears of worm wheels, plugs, bearings of sliding of rings
Sheets in the size (450-980) х (600-1980) mm. thickness-0,5-200,0 mm
Carpentry phenolic cotton cloth ПТ GOST 5-78
Cotton fabric, phenol formaldehyde pitch
105° С
For manufacturing details for which mark ПТК is intended, but working at lower loadings
(450-980)х(600-1980)mm , thickness — 0,5-70,0 mm
Phenolic cotton cloth rod 1class и 2 class , GOST-5385-74
Cotton fabric, heat-convertible binding
105° С
For work in transformer oil and on air in conditions of normal relative humidity
Diameter of 8,0-25,0 mm and 30,0-200,0 mm., length 500 and 1000 mm
The name of parameters
Unit of measure
А
ПТК
ПТ
Breaking point at a bend to perpendicularly layers, not less
МPа
90
152
142
Breaking point at a stretching, not less
МPа
45
-
-
Breaking point at compression in parallel layers, not less
МPа
-
160
155
Impact strength on Charpy on samples with a cut, not less
kJ / m2
With a cut 7,8
36
36
Density
g/сm3
1,3-1,4
1,3-1,4
1,3-1,4
Water absorption, no more for sheets thickness of 3,5 mm
mg
166
-
-
Water absorption, not less
%
-
0,7
0,7
Specific volumetric electric resistance, not less after air-conditioning in conditions 24h/ 23 With / 93 %, for sheets of thicknesses. 8,0 mm
Оhm- m
1-106
-
-
Penetrative pressure in parallel layers (one-minute testing) in conditions of M (90), transformer oil, not less